ioModule

To define a KT-MOD-IO16 for a KT-400, a KT-1, or a KT-2 controller, click the ioModule tab, and complete the following steps:

  1. Select a controller from the Controller list, and click the ADD button.
  2. In the ioModule area, type the name of the ioModule in the language field.
  3. In the Serial Number field, type the serial number.
  4. Select one of the following terminal banks:
    • Terminals 1 - 4
    • Terminals 5 - 8
    • Terminals 9 - 12
    • Terminals 13 -16
    For each terminal, select one of the following action options:
    • Not in use: this is the default setting. Select to indicate the terminals are not in use.
    • Use as input: select to use terminals of inputs/outputs as inputs. EntraPass uses the same setting for EOL as the controller settings. If you want to change EOL settings, use the Input menu. For more information, see Configuring specific controller parameters in the Inputs field, select an input bank from the list.
      Note: You cannot use an input bank on multiple devices. When you use it on one device, it is no longer available until you delete the configuration.
    • Use as relay: select to use terminals of inputs/outputs as relays. In the Relays field, select a relay bank from the list.
      Note: You can define a relay bank on multiple devices, they mirror each other.
    • Use as elevator: select to use terminals of inputs/outputs as elevator doors. Two further options become available:
      • Use as outputs
      • Use as floor confirmation (inputs)

    Use as outputs

    1. In the Elevator field, select an elevator from the list.
    2. In the Elevator outputs field, select the elevator output bank from the list.
    Note: You can define an elevator output bank on multipe elevators, they mirror each other.

    Use as floor confirmation (inputs)

    1. In the Elevator field, select an elevator from the list.
    2. In the Elevator inputs field, select an elevator input from the list.
      Note: You cannot use an input bank on multiple devices. When you use it on one elevator, it is no longer available, until you delete the configuration.

    Terminals 9 -12

    In addition to the Not in use, Use as input, and Use as elevator options, Use as SPI is available for terminals 9 -12.

    Use as SPI: select to use terminals 9 -12 as SPI relays. In addition to the 32 SPI relay modules defined directly in the SPI tab, you can add another 32 relay SPI modules using the ioModule tab.

    To continue the configuration, complete the following steps:
    1. Click the SPI tab, and click the Output module on ioModule tab.
    2. If you have defined more than one ioModule, select the one you want from the ioModule list.
    3. In the Relay 1 -8 tab, select one of the following options:
      • Not used
      • Used as relays
      • Use as elevator equipment
        Note: You can define relays on the SPI expansion module, and on the ioModule. For example, for the KT-1 controller, if you define relays 1 - 4 on an ioModule, and an SPI expansion module, it lights up on the controller, the ioModule, and the SPI expansion module.
  5. To remove a module, click the REMOVE button.