Intrusion panel integration within the global gateway and KT-NCC
You can integrate an intrusion panel through a global gateway, with or without a KT-NCC controller. Global gateways support the following panels:
- DSC MaxSys, Gateway serial connection
- DSC MaxSys, KT-400/KT-1 serial connection
- DSC PowerSeries, Gateway serial connection
- DSC PowerSeries, KT-400/KT-1/KT-2 serial connection
- Honeywell Galaxy, Gateway IP connection (under license)
- DSC PowerSeries Neo HS2016, HS2032, HS2064, and HS2128 serial connection
- DSC PowerSeries Pro HS3032, HS3128, and HS3248 IP connection
KT-NCC gateways support the following panels:
- DSC MaxSys, KT-NCC serial connection
- DSC MaxSys, KT-400/KT-1 serial connection
- DSC PowerSeries, KT-NCC serial connection
- DSC PowerSeries, KT-400/KT-1/KT-2 serial connection
- DSC PowerSeries Neo HS2016, HS2032, HS2064, and HS2128 serial connection
- DSC PowerSeries Pro HS3032, HS3128, and HS3248 IP connection
Note: Before defining an integration panel in
EntraPass, ensure that no partition is armed. If a partition is armed,
you cannot program the panel.
- On the EntraPass workstation, click Devices and click Integrated Panel.
- Click the New icon, and, in both language fields, enter a name for the panel.
- From the Panel list, select a panel.