Defining auxiliary outputs (LED and buzzer)

When you define a controller or a KTES, you can also change the assignment of auxiliary outputs. On the EntraPass workstation, click Devices and click Output.

  1. Select the first undefined output; its check box is not gray. Select it to enable the language fields, and then assign names to it.
  2. Choose the Operating mode option.
  3. Assign a door to the output from the Selected doors list.

The following table summarizes how output zones are used by the system.

Table 1. How the system uses output zones
Auxiliary output Use Controllers
1 LED (Door 1) KT-100, KT-200, KT-300 and KTES
2 Buzzer (Door 1)
3 LED (Door 2) KT-200 & KT-300
4 Buzzer (Door 2)
3 LED (Door 1) KT-400
4 Buzzer (Door 1)
7 LED (Door 2)
8 Buzzer (Door 2)
11 LED (Door 3)
12 Buzzer (Door 3)
15 LED (Door 4)
16 Buzzer (Door 4)