Configuring general parameters for Kantech controllers

  1. Click the Devices tab, click Controller, and, from the Site filter list, select a site filter.
  2. Select the Gateway. For information about configuring a gateway, see Gateway Configuration.
  3. From the Connection list, select the connection where the controller is located. For more information about configuring a connection, see Connection Configuration.
  4. From the Controller list, select the controller you want to define. Once selected, the language section is enabled. You may rename the selected controller.
  5. From the KT controller type list, select a controller type. Once selected, the language section is enabled. You may rename the selected controller.
    • Assign a meaningful name to the controller in the language section, and click the Save icon. After you save, the Controller type list is disabled.
    • The system prompts you to use the Express Setup program. Click Yes to continue. If you click No, you must manually configure these devices in their respective definition menus (doors, relays, inputs and auxiliary outputs).
      Note: In EntraPass, you can install two types of readers on the same controller (primary and secondary). This feature is only available with KT-100, KT-300 under Global and multi-site Gateways. For KT-400, KT-1, or KT-2, 8 different reader types can be loaded (this feature is supported with firmware 1.06 and later).On a given controller, all reader types must be the same (Wiegand or ABA).
  6. Select the reader installed on your controller from the Reader type lists. Check Table 1 for the reader types and the controller types.
    Note: The "plus_button.png" icon allows you to install a custom driver for a specific controller. Use this icon to add the driver in the Reader+ Driver table, making it available the next time you want to configure a new controller.
    Table 1. Reader types
    Reader Types KT-100 KT-200 KT-300 KT-400/KT-1/KT-2
    ABA with Type CNPID Cards Yes Yes Yes
    BC-201 - CF100 Yes Yes Yes
    BC-201 Bar code with Polaris Cards Yes Yes Yes Yes
    CARDKEY Yes Yes Yes
    CASI-RUSCO 26/28-Bit Wiegand Yes Yes Yes
    CHECKPOINT Sielox Format Yes Yes Yes
    CHUBB Yes Yes Yes
    DORADO ABA clock and data Yes Yes Yes
    DORADO ABA Wiegand Yes Yes Yes
    DORADO EMPI 26-Bit Yes Yes
    DORADO EMPI 34-Bit Yes Yes Yes
    FIPS 201 75-bit no expiry date Yes
    FIPS 201 75-bit with expiry date Yes
    h20302, 37-Bit Yes Yes Yes Yes
    HID CORPORATE 1000 Generic Yes Yes Yes Yes
    HID iClass 37-Bit No Party Yes
    HID KSF (Kantech Security Format) Yes Yes Yes Yes
    HUGHES 36-Bit - CF104 Yes Yes Yes
    INDALA old 27-Bit Format Yes Yes Yes
    INTERCON Yes Yes Yes
    ioProx Dual Driver (26-Bit and XSF) Yes Yes Yes Yes
    ioProx Kantech 26-Bit Wiegand Yes Yes Yes Yes
    ioProx Kantech XSF Format Yes Yes Yes Yes
    ioProx UK 31-Bit Wiegand Yes
    KRONOS Card with Bar Code Reader Yes Yes Yes
    Mifare 32-Bit CSN Yes Yes Yes Yes
    Mifare 34-Bit AID 517A Yes Yes Yes
    Mirage 135 Yes Yes Yes
    NCS Yes Yes Yes
    Northern 32-Bit with NR1 Reader Yes Yes Yes
    Northern 34-Bit with Hughes Reader Yes Yes Yes
    Paramount Farm 32-Bit Wiegand Yes Yes Yes Yes
    Polaris 1 - CF101 Yes Yes Yes
    Polaris 1 with 10-Digit Cards Yes Yes Yes
    Polaris 1 with 16-Digit Cards Yes Yes Yes
    Polaris 1 with Polaris Cards Yes Yes Yes Yes
    Polaris 2 ABA with 10-Digit Cards Yes Yes Yes
    Polaris 2 ABA with 16-Digit Cards Yes Yes Yes
    Polaris 2 ABA with Polaris Cards Yes Yes Yes Yes
    Polaris 2KP ABA with 10-Digit Cards Yes Yes Yes
    Polaris 2KP ABA with 16-Digit Cards Yes Yes Yes
    Polaris 2KP ABA with Polaris Cards Yes Yes Yes Yes
    Polaris 32/35/37 CHRS - CF103 Yes Yes Yes
    RBH 50-Bit Card Driver Yes
    SCHLAGE 1030 and 1040 Card Format Yes Yes Yes
    Sensor 26-Bit Wiegand Standard Yes Yes Yes Yes
    Sensor 34-Bit Wiegand Yes Yes Yes Yes
    SFT-R50 26-Bit Yes Yes Yes
    Shadow PROX Yes Yes Yes Yes
    Siteguard Format Yes Yes Yes
    Wiegand 26/28-Bit - CF102 Yes Yes Yes
    WLS Wireless 26-Bit Yes Yes Yes
    WLS Wireless Shadow Prox and HID Yes Yes Yes
  7. Select the keypad installed on your controller from the Keypad type list. Check Table 2 for the keypad types and the controller types.
    Table 2. Keypad types
    Keypad Types KT-100 KT-200 KT-300 KT-400/KT-1/KT-2
    KP-1003H Yes Yes Yes
    KP-500, KP-2000, KP-2500, KP-3000 Yes Yes Yes
    ioProx with Integrated Keypad (8-Bit Burst) Yes Yes Yes Yes
    POL-2KP - 5-Digit Integrated Keypad Yes Yes Yes Yes
  8. Use the Disable controller polling when you need to put the controller in disable mode. In disable mode, the controller is never polled and all status requests from this specific controller send a message that this controller is disabled.
    Note: This option can be used when a controller is removed temporarily but must not be deleted. For example, if the controller is under repair. It also allows operators to easily set up the software before the physical installation is completed.
  9. Select the Vital LED mode (for KT-1 and KT-2 only). For more information, refer to the KT-1 Installation Guide or to the KT-2 Installation Guide.
  10. Select between On demand and Always on for the Status LED (for KT-1 or KT-2 only). For more information, refer to the KT-1 Installation Guide or to the KT-2 Installation Guide.