Defining General Options for an Output

  1. From the Devices configuration window, select the Output button.
    Note: The Miscellaneous section is hidden in the case of using the KT-400 system because the items are already defined in the Gateway/KT-400 events.
  2. Select a Site filter from the first drop-down list.
  3. Select the Gateway.
  4. From the Connection drop-down list, select the connection where the controller is located.
  5. From the Output drop-down list, select the output you want to define. Once selected, the language section is enabled. You may rename the selected output.
  6. From the General tab, specify the Operating mode for the output device (default is Normal ):
    • Normal : The output is switched to ground when it is activated.
    • Inverse : The output is an open circuit (not grounded) when it is activated.
  7. In the Selected doors section, select which door will affect the output you are configuring:
    • First door: Only the first door port will follow the state programmed for these events.
    • Second door : Only the second door port will follow the state programmed for these events.
      Note: This option is not available with KT-100 and KTES.
  8. Set the Activation period (m:ss) delay . It defines the activation time in seconds during which the output remains active when it is programmed for a temporary activation. It will leave the output activated indefinitely, regardless of the activation type. Values range from 1 sec to 4 min:15 secs. Default is 5 secs.
    Note: This option is not available when you are using the KT-400 or the KTES.

    If you are using the Video Integration feature, EntraPass enables you to assign all system components into a video view, the same way you assign them to a system interactive floor plan (graphic). To do this, you simply select the video view where you want the system component (Workstation, site, gateway, controller, etc.) to appear.