KT-300 combus modules
Five Combus modules can be connected to a KT-300:
- KT-PC4108 (8-zone input expansion module). This module has a tamper contact input.
- KT-PC4116 (16-zone input expansion module). This module has a tamper contact input.
- KT-PC4204 (4-relay/power supply expansion module). It has a tamper contact input and also includes a built-in 12VDC, 1A power supply for field devices.
- KT-PC4216 (16-zone output expansion module). It can be used for elevator control, although additional hardware may be required.
- KT-LCD3 (Kantech 32-character liquid crystal display). The LCD is green (normal status), red (power failure) and yellow (trouble).
- If a Combus module is installed to the KT-300 controller, click the Combus module configuration button. Undefined Combus terminals are identified by red flags/bullets. Once a module has been defined, it is identified by a green flag.
- To define a module, select one, then click the Define button (lower part of the window). The Enter Combus module serial number message box appears.
-
Enter the module’s serial number, then click OK.
Note: To obtain this number, you have to activate the Tamper switch or to press any key on the keyboard. The Combus serial number is displayed in the Desktop Message.
- Assign names to the modules in the language fields.
-
Check the options related to the module you want to configure (if these are displayed in the window).
Note: Usage options of a module vary according to the selected Combus module. For example, installing the KT3-LCD and checking the options Combus low power and Display date and time will allow the KT-300 to report Combus low power conditions and to display the date and time.
Table 1. The options associated with each module Combus type Options Additional options KT3-LCD Combus low power, display date and time No additional options KT-PC4108 Tamper alarm, Combus low power 8-input module KT-PC4116 Tamper alarm, Combus low power 16-input module KT-PC4204 Tamper alarm, Combus low power, Low battery, Power failure, lower auxiliary power Used as relays (1-4) KT-PC4216 Tamper alarm, Combus low power Used as outputs - Check the Combus low power option so that the KT-300 will report any Combus low power condition.
- Check Display date and time option so that LCD can display the date and time.
- When you have finished configuring the Combus module, click the OK button to go back to the Status relay tab.
-
Associate a Local activation relay for Power failure, Combus failure and Combus low power
(multi-site Gateway only). If you want to assign a specific relay, you may click the three-dot button and select a specific relay or group of relays.
Note: To configure local activation relay, you must configure relays (Devices > Relays), and then select specific relays for local activation.
-
Under Priority call type, assign the call type option that best suits failure event reporting (multi-site Gateway only). To access the Priority call type feature, the site connection type must be set to Modem.
Note: For more information, see Connection Configuration.