Double/Triple swipe actions
- Activate relay : A relay or relay group can be selected.
- Deactivate relay : A relay or relay group can be selected.
- Lock door : Relock on access on double/triple swipe is automatically checked and disabled
- Request to arm granted - Alarm interface : Equivalent to an arm door manual operation including panel partitions arming functionality. When this action is selected on a global or a KT-NCC gateway, it is only performed when the door is configured as an arming reader in one or more alarm systems. The operator needs to use a double or triple swipe to arm an alarm system. The double/triple swipe conditions are first verified and then the arming conditions of the alarm system.
- Temporarily activate relay : A relay or relay group can be selected. A delay can be entered. (between 00:00:01 and 18:12:15).
- Temporarily unlock door : Relock on access on double/triple swipe is automatically checked and disabled. A delay can be entered (between 00:00:01 and 18:12:15).
- Toggle door lock: Relock on access on double/triple swipe is automatically checked and disabled.
- Toggle relay : A relay or relay group can be selected.
- Unlock door : Relock on access on double/triple swipe is automatically checked and disabled.