Configuring an OSDP reader to a KT-400 or KT-4 controller

  1. On the EntraPass workstation, click the Devices tab, and click Controller.
  2. From the Controller list, select the controller that the reader is connected to.
  3. In the Controller window, click the KT-400 tab.
  4. From the COM2 Protocol list, select OSDP.
    The RS-485 baud rate changes to 9600 and the Reader template changes to Default OSDP reader template. You can update these items.
  5. To add readers, complete one of the following options:
    • Use the following preferred option to manually add readers:
      1. Click the KT-400 tab.
      2. Click Add and, in the Address column, select or type the OSDP reader address. Accepted values range from 0 to 126.
      3. In the Door column, select the door to associate with the reader.
      4. Click Save.
    • Use the following option to automatically add unassigned readers. This feature only works for addresses 0 to 31 at the default baud rate of 9600:
      1. On the Controller window toolbar, click the Request unassigned modules icon.
      2. In the Request unassigned modules window, right-click the appropriate reader and select Assign module.
      3. Click Save.