Associating Events with Auxiliary Outputs
System events can trigger auxiliary outputs. You can define how each event will trigger the output.
- Select the Definition tab to associate a door event with an auxiliary output.
-
In the Options column, associate an event with an output state. Default is None .
- Steady timed : The output given this option will not flash, it will remain activated for the specified activation period and will return to normal state when the activation period is over.
- Flash timed : The output will flash and remain activated for the specified activation period and will return to its normal state when the activation period is over.
- Steady : The output given this option will not flash, it will remain activated until it returns to normal condition.
- Flash : The output will flash and remain activated until its condition returns to normal.
Note: The on-off delays for the outputs are pre-defined during the gateway definition. For details, see EntraPass Gateways Configuration. Events for timer on/off vary depending on the type of the selected gateway. A multi-site Gateway supports up 34 events and an Global Gateway supports up to 22 events.