How to set up the ioSmart
Connect the Kantech ioSmart card reader to a supporting KT-400, KT-1, or KT-2 controller. The ioSmart supports both Wiegand and RS-485 connections to the controller.
If you connect the ioSmart using a Wiegand connection, use the Express Setup Program to configure the reader. For more information, see Express setup.
If you connect the ioSmart using an RS-485 connection, complete the following steps:
- On the EntraPass workstation, click the Devices tab, and click Controller.
- From the Controller list, select a controller, and click on the ioSmart tab.
- Click +Add to add an ioSmart reader to the controller.
- In the Serial number field, enter the ioSmart reader's serial number.
- From the Door list, select the associated door.
- If the ioSmart reader includes a keypad, select the Keypad check box.
- Click Terminals to configure the ioSmart reader's inputs and outputs.
-
In the Setup terminals window,
in the I1 and I20 panes, select the terminal functions.
- Disabled
- Single input
- Dual input
- Lock output
- Relay
Note: You can configure I1 and I2O for a maximum of four inputs, using both I1 and I2O in dual inputs mode, or for two inputs and one output, a lock output or a relay. - Click the KT-1/KT-2 or the KT-400 tab, and, from the RS-485 baud rate list, select the appropriate baud rate for your system.
- In the Reader template field, click the Three dot icon, and select a reader template.
- To configure the reader template, on the EntraPass workstation, click the Devices tab, and click Reader template.