KTES - EDIT ADVANCED SETTINGS

1.      Click in the textbox at the top left corner and change the KTES' name.

2.      Connection: This is the site for which the KTES is assigned.

3.      Tenant List Capacity: By default, the capacity is 250 tenants unless you have registered for 3000 tenants total.

4.      Serial number: The serial number is unique to each KTES. It is used for communication between the KTES and the EntraPass software. Default value is 00000000.

5.      EOL resistor type: This parameter defines the input termination as None for no end‐of‐line resistor (dry contact), Single for single end‐of‐line resistor (5.6K) or Double for double end‐of‐line resistor (2 * 5.6K). Default value is None.

6.      Tenant List: Select a tenants list from the drop-down list. Default value is empty.

7.      Map: Select a map from the drop-down list.

8.      Video View: Select a video view from the drop-down list.

Access

9.      Reader Type: This is the Wiegand Interface output format to be sent to the KTES. Default value is Kantech XSF.

Relay Activation

10.  Heater Kit Relay: Relay that will be activated when cabinet inside temperature falls below +5oC. Default value is none.

Postal Lock

11.  Input: This is the input corresponding to the door postal lock (0 to 4). Select an input and click OK.

12.  Schedule: This is the schedule inside which the input, corresponding to the postal lock, generates a valid postal lock request when that input is in alarm.

13.  Relay: Relay that will be activated with an entry request from the front door postal lock. Default value is none.

14.  Link With user: To link a user to the postal lock, click the Link With user button. Click the Select button and select a user. You can also leave the checkbox unselected and enter a Card Number.

Visitor Call Setting

15.  Keypad key for access granted by tenant: This telephone key can be used by a tenant to grant access to a visitor. Default value is 9.

16.  Keypad key for access denied by tenant: This telephone key can be used by a tenant to deny access to a visitor. Default value is *.

17.  Keypad key for auxiliary relay by tenant: This telephone key can be used to grant access to a visitor that is using a secondary entrance. Default value is empty.

18.  Talk Time: This is the maximum talk duration in seconds for a normal call between a visitor and a tenant (10 secs to 59 min:59 secs). Default value is 40 secs.

§        Extended: This is the maximum talk duration in seconds for a extended call between a visitor and a tenant (10 secs to 59 min:59 secs). Default value is 60 secs.

§        Talk Time Remaining Warning: The system sends a warning ring (a beep sound), a certain number of seconds (depending on the value entered) to indicate the end of the allowed talking period (1 sec to 59 min:59 secs). Default value is 10 secs.

19.  Number of Rings Before Answer: This is the maximum number of rings allowed for a tenant to answer (4 to 16). Default value is 5.

§        Extended: This is the maximum number of rings allowed, for a tenant with the extended option, to answer (4 to 16). Default value is 10.