The Kantech Telephone Entry System (KTES) is a telephone entry system that is suited for small and large applications with a separate access control system, or in applications that require telephone entry access only. This system provides visitor access control for a variety of applications: apartment buildings, gated communities, condominiums, office buildings, factories, and industrial sites. Visitors use the KTES to communicate directly with a tenant and are easily identified by voice communication. The tenant can grant or deny the visitor access directly from a telephone land line or a cellular phone. Designed as a stand‐alone unit, the system controls one door, auxiliary relay, and supports postal lock access. For larger commercial installations, the KTES integrates with EntraPass Web through a Multi‐site Gateway and KT‐controllers to provide a complete access control solution. The entire programming of the system can be done directly on the keypad or remotely from a PC via EntraPass Web. The system reports all events directly to EntraPass, where you can obtain a detailed event log. Additionally, programmed alarms can be reported to a pager and/or to the EntraPass system via an integrated modem. For more information on the KTES, please refer to the KTES Installation Manual, DN1769 and the KTES Programming Manual, DN1770.
1. Click in the textbox at the top left corner and change the KTES' name.
2. Connection: This is the site for which the KTES is assigned.
3. Tenant List Capacity: By default, the capacity is 250 tenants unless you have registered for 3000 tenants total.
4. Serial number: The serial number is unique to each KTES. It is used for communication between the KTES and the EntraPass software. Default value is 00000000.
5. EOL resistor type: This parameter defines the input termination as None for no end‐of‐line resistor (dry contact), Single for single end‐of‐line resistor (5.6K) or Double for double end‐of‐line resistor (2 * 5.6K). Default value is None.
6. Tenant List: Select a tenants list from the drop-down list. Default value is empty.
7. Map: Select a map from the drop-down list.
8. Video View: Select a video view from the drop-down list.
9. Reader Type: This is the Wiegand Interface output format to be sent to the KTES. Default value is Kantech XSF.
10. Heater Kit Relay: Relay that will be activated when cabinet inside temperature falls below +5oC. Default value is none.
11. Input: This is the input corresponding to the door postal lock (0 to 4). Select an input and click OK.
12. Schedule: This is the schedule inside which the input, corresponding to the postal lock, generates a valid postal lock request when that input is in alarm.
13. Relay: Relay that will be activated with an entry request from the front door postal lock. Default value is none.
14. Link With user: To link a user to the postal lock, click the Link With user button. Click the Select button and select a user. You can also leave the checkbox unselected and enter a Card Number.
15. Keypad key for access granted by tenant: This telephone key can be used by a tenant to grant access to a visitor. Default value is 9.
16. Keypad key for access denied by tenant: This telephone key can be used by a tenant to deny access to a visitor. Default value is *.
17. Keypad key for auxiliary relay by tenant: This telephone key can be used to grant access to a visitor that is using a secondary entrance. Default value is empty.
18. Talk Time: This is the maximum talk duration in seconds for a normal call between a visitor and a tenant (10 secs to 59 min:59 secs). Default value is 40 secs.
§ Extended: This is the maximum talk duration in seconds for a extended call between a visitor and a tenant (10 secs to 59 min:59 secs). Default value is 60 secs.
§ Talk Time Remaining Warning: The system sends a warning ring (a beep sound), a certain number of seconds (depending on the value entered) to indicate the end of the allowed talking period (1 sec to 59 min:59 secs). Default value is 10 secs.
19. Number of Rings Before Answer: This is the maximum number of rings allowed for a tenant to answer (4 to 16). Default value is 5.
§ Extended: This is the maximum number of rings allowed, for a tenant with the extended option, to answer (4 to 16). Default value is 10.