Panel component tab (Bentel, DSC Maxsys, PowerSeries Neo and Pro)
This feature depends on the type of intrusion panel. You must create the device in EntraPass for the DLL to download to the corresponding gateway or KT-400. After it downloads, the auto-detection becomes active.
-
Define the Zone, Partition, User, and Virtual Zone parameters.
The following table lists the parameters' maximum values.
Table 1. Parameter maximum values Parameter PC1616 PC1832 PC1864 HS2016 HS2032/3032 HS2064 HS2128/3128 HS3248 Zones 32 32 64 16 32 64 128 248 Partitions 2 4 8 2 4 8 8 32 Users 48 72 95 48 72 500 1000 1000 Virtual Zones 16 32 32 32 32 - Select the number of Zones. Click the button in the upper left to display a table that shows all the defined zones. Click View or Edit to view or edit the selected zone.
- Select the number of Partitions. Click the button in the upper left to display a table that shows all the defined partitions. Click View or Edit to view or edit the selected partition.
- Select the number of Users. Click the button in the upper left to display a table that shows all the defined users. Click View or Edit to view or edit the selected user.
-
Select the number of Virtual
Zones. This is available only for Neo panels connected to a KT-1 or a
KT-400. A corresponding number of virtual inputs are added in Integrated Component window. Configure virtual zones
in the Integrated Panel window to view all
zones. Configure virtul zones in the Integrated
Component window to view one zone at a time.
Note: The default number of Virtual Zones is the maximum value shown in Table 1. The purpose of this feature is to create virtual zones in an alarm panel that receives commands from groups of selected inputs, doors, and other events of a gateway. These commands are then transmitted from the panel to a central station.
The DSC PowerSeries Neo 1.1 integrated panel can support 16 or 32 virtual zones: 16 virtual zones for HS2016 and 32 virtual zones for HS2032/3032, HS2064, HS2128/3128, and HS3248.
This feature is available only when using KT-400, KT-1, and KT-2 controllers. You require the following firmware: KT-400 v1.16.xx, KT-401 v1.22.xx, KT-1 v1.02.xx, or KT-2 any firmware versions.
-
Click Virtual Zone List. The
displayed table allows you to map Kantech components to DSC virtual zones.
Note: The Physical Zone column is displayed only with a valid DSC panel communication.
- Click the Door,
Input and Event tabs, and select a physical zone number and the type of
event (Alarm, Trouble or Tamper) to be
sent to the central. View the remaining available zones on the counter in the
upper right.
Table 2. Events sent to the virtual zone Component EntraPass Event Report Alarm Report Trouble Report Tamper Input Input in alarm / Input restored or in normal condition X Input in trouble / Input in trouble restored X Input tamper in alarm / Input tamper restored X Door Door forced open / Door forced open Restored X Door open too long / Door open too long restore X Door lock device failure / door lock device failure restored X Duress Duress feature X Controllers Controller AC power failed / Controller AC power restored X Tamper switch in alarm / Tamper switch restored X Controller Auxiliary power failure / Controller Auxiliary power restored X Controller reader power failure / Controller reader power restored X Controller battery power failure / Controller battery power restored X Controller module communication failure /Controller module communication restore X Controller DC power failed / Controller DC power restored X Controller lock power failed / Controller lock power restored X Controller power trouble (KT-1) X Access Denied Access denied - Bad card status X Access denied - Card lost or stolen X Access denied - Card expired X - Click Add to add a new event in the list or click Remove to remove the selected event.
- Click Save or Cancel to return to the Integrated Panel window.
- Printing: Use the Print button from the Virtual Zone Summary section to send the virtual zone configuration parameters to the central.
Figure: Virtual zone printing
- Click the Door,
Input and Event tabs, and select a physical zone number and the type of
event (Alarm, Trouble or Tamper) to be
sent to the central. View the remaining available zones on the counter in the
upper right.