Programming REB-8 elevator controllers
REB-8 relay expansion boards may be used as a cost-efficient alternative for elevator control. With a REB-8 expansion board added to a KT-200, the software may control up to two elevator cabs per controller.
- In the KT-200 definition window, select the REB-8 elevator controller option. When the option is selected, an Elevator tab appears beside the KT-200 tab. The REB-8 definition section is only active when REB-8 are used as relays.
- Select the Elevator tab to configure the REB-8 elevator controllers. Up to four REB-8 elevator controllers are supported.
-
Specify the number of REB-8 that are installed on the controller. The selection
is cumulative. For example, if four REB-8 are installed, the first three
checkboxes have to be checked also. The following table summarizes how REB-8 are
assigned to floors and to elevator cabs.
Table 1. REB-8 assigned to floors and elevators Number of REB-8 Number of Floors Number of Cabs 1 1 to 8 Cab 1 2 9 to 16 Cab 1 3 1 to 8 Cab 2 4 9 to 16 Cab 2 Note: The Inputs column refers to the REB-8 terminals. When floors have been defined (in the Floor menu), the Floors column contains the floors that are associated with the inputs. -
In the Floors column, select the floors associated with
REB-8 controller terminals. For information about floor definition and door group
definition, see Doors
Configuration.
Note: There is no floor confirmation when an REB-8 is used as an elevator controller.