Redundant gateway operations

If a redundant server has been used in a number of ways. It becomes active following the failure of the primary gateway. It can also be manually switched to. This may be used for primary gateway maintenance. If a redundant gateway is automatically switched to the primary gateway can only be reinstated manually.

  1. From the EntraPass workstation main window, select the Operation tab and click the Gateway button to open the Gateway dialog where all the gateways connected to your system are listed.
  2. Select your multi-site gateway to see the status of all gateways.
  3. Right-click on a gateway to view options.
  4. Select as online gateway to reinstate primary gateway.

A green square highlights the active gateway. A yellow square highlights non-active gateways.

Note: Gateways can be reloaded individually or together. To reload a gateway individually right-click the gateway and select Reload. To reload the gateways together right-click the multi-site gateway and select Reload. This reloads all associated gateways.