Integrated component configuration

Use the Integrated Component window for any type of panel component, including partition and zone, under any type of panel, including intrusion and temperature control.

  1. On the EntraPass workstation, click Devices and click Integrated Component.
  2. From the Component list, select the component.
    Note: You can use the list in the toolbar to sort the displayed components by type.
  3. From the Component type list, select the component type.
  4. Click Configuration Form to display the DSC Power Series window.
  5. For a User component type, enter the User access code. This code is a PIN number used for arming or disarming a partition.
  6. For a Simplex panel, select proper values to define the fire panel device point. After the device is granted an address (manually or automatically from IDNet import), the user cannot change it unless the point is deleted and another one is created.
  7. For a Virtual Zone, from the Component type list, select a component type. You can select door, input, or event.

  1. For an Event component type, select an event. For a list of events based on the selected component type, see Table 1.
  2. For a Door or Input component type, indicate the component source (controller).
  3. Select the appropriate Component action to be reported for the virtual zone and click OK.
The purpose of this feature is to create virtual zones in an alarm panel that receive commands from groups of selected inputs, doors, and other events of a gateway. These commands are then transmitted from the panel to a central station.
Note: The DSC PowerSeries Neo 1.1 integrated panel can support 16 or 32 virtual zones: 16 virtual zones for HS2016 and 32 virtual zones for HS2032/3032, HS2064, HS2128/3128, and HS3248.
Note: This feature is available only when using KT-400, KT-1, and KT-2 controllers. You require the following firmware: KT-400 v1.16.xx, KT-401 v1.22.xx, KT-1 v1.02.xx, or KT-2 all firmware versions.
Table 1. Events sent to the virtual zone
Component EntraPass event Report alarm Report trouble Report tamper
Input Input in alarm / Input restored or in normal condition X
Input in trouble/ Input in trouble restored X
Input tamper in alarm / Input tamper restored X
Door Door forced open / Door forced open restored X
Door open too long / Door open too long restore X
Door lock device failure / door lock device failure restored X
Duress Duress feature X
Controllers Controller AC power failed / Controller AC power restored X
Tamper switch in alarm / Tamper switch restored X
Controller Auxiliary power failure / Controller Auxiliary power restored X
Controller reader power failure / Controller reader power restored X
Controller battery power failure / Controller battery power restored X
Controller module communication failure /Controller module communication restore X
Controller DC power failed / Controller DC power restored X
Controller lock power failed / Controller lock power restored X
Controller power trouble (KT-1) X
Access Denied Access denied - Bad card status X
Access denied - Card lost or stolen X
Access denied - Card expired X

  1. If the Video feature is enabled, the Video view field appears (for zones and partitions only). If this is the case, select the video view in which you want the defined component to appear. For information about defining video views, see Video Views Definition.
  2. From the Graphic list, select the graphic to which the application is assigned, if applicable (for zones and partitions only). For information about defining graphics, see Graphics Definition.
    Note: The Details button is available only for a User or a Virtual Zone component type.
  3. Click Save.
To complete the configuration, see Manual Operations on Integrated Panels.