Defining Door Options for Controllers and the KTES (multi-site Gateway Only)

The following tab only appears when KT-100, KT-300, KT-400, KT-1, and KT-2 controllers and the KTES have been configured in a multi-site Gateway.

Click the Options and alarm system tab (or Options for a KTES).

  • Supervised door lock device: use this feature in specific applications such as bank vaults to compensate for the slow motor locks. Adding this delay avoids false door forced open alarms if a user opens the door before it has been completely secured at the end of unlocking delay. Select the Supervised door lock device check box to enable this option.
  • Motor lock delay (does not apply to KTES) : Enter the time period (hh:mm:ss) after which the door will be considered locked. Values range from 0s to 18 h:12 min:15 secs. The default value is 0:00 for inactive. For example, if this delay is set to 5 seconds and unlocking delay is 20 seconds after access granted; the lock output will d deactivate after 15 seconds and no door forced open alarm will be generated if the door is opened during the last 5 seconds.
  • If a second card read is required, select a schedule from the Second card schedule required (two-man rule) list (does not apply to KTES) .
  • Relay to follow lock output (Only available for KT-400 and KTES): The relay follows the lock output status.
  • Multi-factor authentication: available for go Pass cardholders presenting at a door. To define multi-factor authentication for go Pass, select one of the following options:
    • None: multi-factor authentication is not enabled, present a card to the reader.
    • go Pass: present a card to the reader, or go Pass to the door.
    • go Pass + Disable card: present go Pass to the door only, disables an ioSmart reader in RS-485.

    The option you select saves as a global setting and is the default setting when you create a new account and enable go Pass. You can change the setting as required.

    Note: The first type of authentication is an activation e-mail. The second type of authentication depends on the smarphone, use a PIN or biometric identification.
  • Enable duress function on keypad (KTES only): Set this parameter to enable the duress function on the door controller keypad. Employees or tenants use the duress function to signal for help. The operator must enable the duress function. The duress function is unchecked by default. For more information, see KTES Configuration. For more information on the duress function for doors only, see Defining Door Keypad Options.
    Note: When KT-100, KT-300 and KT-400 are installed in a multi-site Gateway, the system offers the ability to interface an external alarm system.