Configuring external alarm system interfaces (multi-site Gateway only)
The following option is only available when KT-100, KT-300, KT-400, KT-1, and KT-2 controllers have been configured in a multi-site Gateway. KT-100, KT-300, KT-400, KT-1, and KT-2 controllers offer the ability to interface with any external alarm system. When you add these Kantech controllers to an existing alarm system, cardholders can arm/disarm an existing system, simply by presenting a valid card on an entry/exit door. Adding a keypad will increase the system security since cardholders will be required to enter a PIN in addition to presenting a card (does not apply to a KTES door). There are two ways of arming/disarming or postponing an external alarm system:
- On a valid card read and with the trigger of an arming input.
- On a valid arming code entered and with the trigger of an arming input.
There may be a combination of the options. For example, an alarm system will be disarmed with a correct access code during a valid predefined schedule and after a valid card read.