Defining the status relay parameters

  1. In the KTES window, click the Status relay tab.
    Note: See Relay Configuration for more information about relay configuration.
  2. Specify the Relay activation parameters:
    • Power failure: This is the relay that can be activated when a KTES AC power failure occurs. The default value is none.
    • Battery trouble: Relay that will be activated if the 12 volts standby battery is disconnected or comes low (under 11.5 volts DC). The default value is none.
    • Tamper in alarm: This is the relay that can be activated when a KTES tamper switch event occurs. The default value is none.
    • Buffer 70% full: Relay that will be activated if the event buffer for the EntraPass software has reach a 70% capacity. The default value is none.
    • Lock power trouble: This parameter defines the relay to be activated in the event of a door lock problem, locking device disconnected or shorted to ground. The default value is none.
    • Other troubles: Relay that will be activated when any other trouble on the KTES occurs. The default value is none.
    • Heater kit activated: Relay that will be activated when cabinet inside temperature falls below +5oC. The default value is none.
    • Postal lock: Relay that will be activated with an entry request from the front door postal lock. The default value is none.
  3. Specify the Pager call type:
    • For each event you can configure a pager call type. You can select No call (the relay activation for that event will not be sent to the pager), Immediate call (the relay activation for that event will be sent immediately to the pager) or Schedule call (the relay activation for that event will be sent to the pager according to the pager call schedule). The default value is No call.
      Note: To specify pager call types for each events, the Pager reporting function must be enabled.