Defining the Pager options

  1. From the KTES window, select the Pager tab.
    Note: For New Zealand: This equipment is not set up to make automatic calls to the Telecom “111” Emergency Service.
  2. Specify the Pager Reporting options:
    • Pager phone number : The pager phone number that events are reported to (24 characters maximum). Default value is empty.
    • Pager call schedule : The schedule number from which the KTES can communicate programmed events, alarms, and troubles to the pager. Select a schedule from the list and click OK.
      Note: See Schedules Definition for more information about schedule definition.
    • Unit ID : The Unit ID identifies theKTES that sent the pager code(0001 to 9999). Default value is 0001.
    • Restore code : The Restore codeis the pager code corresponding to the general event that triggered a zone restore condition (0 to 999). Default value is 0.
    • Alarm code : The Alarm code is the pager code corresponding to the general event that triggered a zone alarm condition (0 to 999). Default value is 1.
    • Tamper code : The pager code corresponding to the general event that triggered a zone tamper condition (0 to 999). Default value is 2.
    • Trouble code : The pager code corresponding to the general event that triggered a zone trouble condition (0 to 999). Default value is 3.
    • Field separator : The Field separator is the character to be used as a field separator or delimiter (*, # or ,). Default value is *.
    • Field ending : TheField ending is used to indicate that the call is completed. Remember that you can enter any signs for the ending parameter (*, # or ,). Default value is #.
  3. Specify the General event pager codes:
    • Tamper in alarm : The pager code that corresponds to a tamper switch problem (0 to 999). Default value is 100.
    • Power failure : The pager code that indicates an AC power failure on the KTES (0 to 999). Default value is 101.
    • Battery trouble : The pager code that indicates a low battery problem on theKTES (0 to 999). Default value is 102.
    • Buffer 70% full : The pager code sent to indicate that the event buffer for the EntraPass software has reach a 70% capacity (0 to 999). Default value is 103.
    • Other troubles : The pager code that corresponds to any other system event that can occur (0 to 999). Default value is 104.
    • Door forced open : The pager code thatcorresponds to a forced open door (0 to 999). Default value is 120.
    • Door open too long : The pager code that corresponds to a door opened for too long (0 to 999). Default value is 121.
    • Door alarm on relock : The pager code that corresponds to a door left opened (0 to 999). Default value is 122.
    • Lock trouble : The pager code that corresponds to a problem with the door locking device supervision (0 to 999). Default value is 123.
    • Keypad disabled : The pager code that corresponds to a keypad disabled condition (when the option is enabled (0 to 999). Default value is 124.
    • Duress alarm : The pager code that corresponds to a duress alarm. A Duress alarm is used by employees or tenants to signal for help (0 to 999). Default value is 125.
    • Access granted : The pager code thatcorresponds to a granted access. An access granted code is sent when the tenant was granted access using his PIN (0 to 999). Default value is 140.
    • Invalid access schedule : The pager code that corresponds to a denied access. An access denied code is sent when the tenant was denied access using his PIN (0 to 999). Default value is 141.
    • Access granted by tenant : The pager code that corresponds to an allowed access by a tenant to a visitor (0 to 999). Default value is 142.
    • Auxiliary relay activated by tenant : The pager code that corresponds to an allowed access by a tenant to a visitor at an alternate entrance, different from the main entrance usually used by the tenants or visitors, for example (0 to 999). Default value is 143.
    • Access denied by tenant : The pager code that corresponds to a denied access by a tenant to a visitor (0 to 999). Default value is 144.
    • Tenant traced : The pager code that corresponds to a granted access for a traced tenant(0 to 999). Default value is 145.
    • Disabled tenant : The pager code that corresponds to an access attempt from a tenant with an invalid status (0 to 999). Default value is 146.
    • Other access denied : The pager code that corresponds to an access attempt from a tenant outside of his assigned schedule (0 to 999). Default value is 147.