Hardware Setup > Sites > Connections
Connections

•  Direct (RS‐232 and USB)

•  Secure IP (KT‐400/KT-1)

•  Secure IP (KTES)

•  Secure IP (IP Link)

•  Ethernet (polling)

Left Panel

•  This panel displays the connections associated with the gateway selected from the drop-down list.

•  Use the Filter... textbox to sort the list  of connections according the characters string you have entered.

Working Area

•  The working area contains the controllers associated to the selected connection. Use a right-click to perform actions on controllers (see next section for details)

Top Right Buttons

•  Add button: Click the Add button to add a new connection to the gateway.

•  Edit button: Click the Edit button to configure the selected connection parameters or use a right-click and select Edit Connection from the contextual menu.

•  Save As button: Click the Save As button to make a duplicate the selected connection or use a right-click and select Clone Connection from the contextual menu..

•  Delete button: Click the Delete button to delete the selected connection from the list or use a right-click and select Delete Connection from the contextual menu.

Note: See Connection Setup for more details.

Controllers

Controllers provide audiovisual feedback on the access decision. Typically, a red/green light (LED) indicator on the reader informs the cardholder that the door is unlocked or that access has been denied. A local door alarm can be installed to provide an audible warning if the door is forced open or remains open after an access. The controller definition tells the system how a controller is being used and what devices are associated with it: (doors, input zones and relays). Controllers may be defined during a connection configuration. EntraPass Web supports five types of controllers: KT‐100, KT‐200, KT‐300, KT‐400 and KT-1. These provide the ability to activate local functions associated with a controller.

•  Add Controller button: Click the Add Controller button to add a new controller to the selected connection with the Express Setup wizard.

•  Edit advanced settings button:  Click the Edit advanced settings button to edit the controller's parameters or use a right-click and select Edit Controller from the contextual menu (see Controller Advanced Settings for more details).

•  Delete button: Click the Delete button to delete the selected controller from the list or use a right-click and select Delete Controller from the contextual menu.

Bottom Bar

•  WatchList button: If a component is "watched", it will be displayed in this list.

•  Zoom buttons: Use the and buttons to make a zoom out or zoom in of the time scale.