1 - In the Doors – Relays – Input column, select the Inputs check box.
2 - Select the input, and click Edit.
3 - In the Primary language field, enter a name for the door.
4 - Optional: In the Secondary language field, enter a name in a different language.
5 - In the Operating mode area, choose Closed or Opened in the Normal condition field to set the normal state of the input.
6 - In the Event message field, choose Alarm or Activation. When you configure event parameters with an input in alarm, or input activated, the system only displays the inputs corresponding to the criteria.
7 - Select a schedule from the Monitoring schedule list. This schedule specifies when the system supervises the condition of the input. When the schedule is valid, a change in an input condition generates an “input in alarm” or “input restore” event.
8 - Select the relay you want to activate from the Activate relay list.
9 - Select the Activate relay temporarily check box if you want to activate the relay according to the temporary activation parameters defined in the Edit relay window.
For each relay, complete the following sections:
• Timing
• Shunt
• Association
• Comments