KTES-Edit Advanced Settings
Hardware Setup > Connections > KTES-Advanced Settings
KTES-Edit Advanced Settings

The Kantech Telephone Entry System (KTES) is a telephone entry system that is suited for small and large applications with a separate access control system, or in applications that require telephone entry access only. This system provides visitor access control for a variety of applications: apartment buildings, gated communities, condominiums, office buildings, factories, and industrial sites. Visitors use the KTES to communicate directly with a tenant and are easily identified by voice communication. The tenant can grant or deny the visitor access directly from a telephone land line or a cellular phone. Designed as a stand‐alone unit, the system controls one door, auxiliary relay, and supports postal lock access. For larger commercial installations, the KTES integrates with EntraPass Web through a Multi‐site Gateway and KT‐controllers to provide a complete access control solution. The entire programming of the system can be done directly on the keypad or remotely from a PC via EntraPass Web. The system reports all events directly to EntraPass, where you can obtain a detailed event log. Additionally, programmed alarms can be reported to a pager and/or to the EntraPass system via an integrated modem. For more information on the KTES, please refer to the KTES Installation Manual, DN1769 and the KTES Programming Manual, DN1770.

1 - Click in the textbox at the top left corner and change the KTES' name.

2 - Connection: This is the connection for which the KTES is assigned.

3 - Tenant List Capacity: By default, the capacity is 250 tenants unless you have registered for 3000 tenants total.

4 - Serial number: The serial number is unique to each KTES. It is used for communication between the KTES and the EntraPass software. Default value is 00000000.

5 - EOL resistor type: This parameter defines the input termination as None for no end‐of‐line resistor (dry contact), Single for single end‐of‐line resistor (5.6K) or Double for double end‐of‐line resistor (2 * 5.6K). Default value is None.

6 - Tenant List: Select a tenants list from the drop-down list. Default value is empty.

7 - Map: Select a map from the drop-down list.

8 - Video View: Select a video view from the drop-down list.

ClosedAccess
ClosedRelay Activation
ClosedPostal Lock
ClosedVisitor Call Setting